Mounting the motor
5.3 Mounting the motor
NOTICE
Damage to the bearing and bearing grease due to liquid at the flange
If liquid accumulates at the flange because of vertical or horizontal mounting, the bearing
and bearing grease may be adversely affected.
• Prevent liquid from accumulating at the flange.
Note
Using the eyebolts
Lift the 1PH3 motors only at the eyebolts.
Note
Cooling air
The motor must be mounted in such a way that the cooling air can flow in and out without
restriction. For more information, see Section "Cooling (Page 31)".
Flange mounting
Mount the motor through a mounting steel flange. Note that for shaft height 132 mm
motors, there are two kinds of flanges for selection. For more information, see Chapter
"Motor dimensions (Page 35)".
Motor variant
Flange mounting
1PH310❑-1❑❑02-❑❑A0
1PH313❑-1❑❑02-❑❑A0
Flange mounting (1PH8 compatible)
1PH313❑-1❑❑04-❑❑A0
64
Screw
4 × M12
4 × M12
4 × M16
Equipment Manual, 01/2021, A5E43087278-004
Tightening torque
84 Nm
84 Nm
165 Nm
1PH3 main motors