Raid Volume Migration; Raid 0; Raid 1 - Edge10 EDGESTORE NAS400 User Manual

Edge10 nas400: user guide
Hide thumbs Also See for EDGESTORE NAS400:
Table of Contents

Advertisement

RAID Volume Migration

Migration is the process of:
Changing the RAID level
Adding disk drives but keeping the same RAID level
In the migration process, the existing RAID Volume is called the Source. The
proposed RAID Volume is called the Target. Each target RAID Volume has
certain requirements and they are different for each RAID level. You must meet
all of the requirements in order to successfully migrate a RAID Volume.
In most cases, you must add one or more disk drives during the migration
process. You can never reduce the number of disk drives.
While the migration is running, you can still access the folders on your RAID
Volume and the data they contain.
The tables below shows the migration options for a source RAID Volume
according to its RAID level. The available target RAID levels are shown with their
requirements.

RAID 0

A RAID 0 source Volume can migrate to the following target RAID levels:
Target
RAID 0

RAID 1

RAID 5
RAID 1
A RAID 1 source Volume can migrate to the following target RAID levels:
Target
RAID 0
RAID 5
Add disk drives.
2 disk drives only.
Only a 1-drive RAID 0 can migrate to RAID 1. Add 1 disk drive.
3 disk drives minimum.
At least 1 more disk drive than the RAID 0 RAID Volume.
Can use same number of disk drives.
3 disk drives minimum.
At least 1 more disk drive than the RAID 1 RAID Volume.