6.2.1
Junction box and terminal diagram
ELHY-Montageanleitung_2021_EN.docx
There is a connection diagram in the terminal box cover. The motor is
voltage switchable for delta connection (Δ) or star connection (Y). On
delivery, the devices are connected in star connection (Y). The phase
sequence for the connection is arbitrary.
6-pin terminal board
Terminal diagram:
Figure 10:
6-pin terminal diagram (dual voltage)
1
Screwed connection for motor cable M25 x 1.5
2
L1
3
PE earthing conductor terminal
4
L2
5
L3
Assembly and installation
Electrical connection
6
6.2
47 / 71