6
Assembly and installation
6.4
Completing assembly
6.3.3
Changing the set time and the reset time
6.4
Completing assembly
52 / 71
Figure 12:
Lifting/lowering valve adjustment parts
1
Screw plug
2
Cylinder casing
3
Regulating plug
4
Guide cylinder
Turning the regulating plug (3) clockwise increases the lifting or
lowering time.
Turning the regulating plug (3) anticlockwise reduces the lifting
or lowering time.
Unscrew screw plug (1).
Turn the regulating plug (3) to set the required set or reset time
Screw in screw plug (1).
After completing assembly, check that the earthing conductor system
is consistent.