6
Assembly and installation
6.4

Completing assembly

6.3.3

Changing the set time and the reset time

6.4
Completing assembly
52 / 71
Figure 12:
Lifting/lowering valve adjustment parts
1
Screw plug
2
Cylinder casing
3
Regulating plug
4
Guide cylinder
Turning the regulating plug (3) clockwise increases the lifting or
lowering time.
Turning the regulating plug (3) anticlockwise reduces the lifting
or lowering time.
 Unscrew screw plug (1).
 Turn the regulating plug (3) to set the required set or reset time
 Screw in screw plug (1).
After completing assembly, check that the earthing conductor system
is consistent.