Limit Switches - EMG ELHY EB 630 Assembly Manual

Table of Contents

Advertisement

4
Functional description
4.4
Position indicators
4.4.2

Limit switches

38 / 71
Standard switches are used as limit switches (other switch types
optionally possible).
Mechanical limit switches (Lm...*)
Table 18:
Mechanical limit switches (Lm...*) - parameters
Parameters
Type
Voltage
Rated current
Continuous current,
max.
Switching voltage, max.
Contact
Protection category
Inductive limit switches (Li...*)
Table 19:
Inductive limit switches (Li...*) - parameters
Parameters
Type
Voltage
Output current, max.
Contact
Switching distance
Protection category
*
Number of signal generators and signal contents:
2
1xSG, lifting rod extended
5
1xSG, lifting rod retracted
7
1xSG, function-dependent intermediate position
3
2xSG, lifting rod extended + lifting rod retracted
4
2xSG, lifting rod extended + function-dependent intermediate position
6
2xSG, lifting rod retracted + function-dependent intermediate position
For detailed information and availability of the respective limit switch
version, please contact EMG Automation GmbH.
Value/size
M3R 330-11y (Schmersal)
24–250 V AC/DC
2.5 A
6 A
250 V AC/DC
Changer
IP65
Value/size
BI 15-CP40-FZ3X2 (Turck)
20–250 V AC/DC
300 mA
NC or NO contact, programmable
15 mm
IP66