4.4

Position indicators

4.4.1

Sensors

ELHY-Montageanleitung_2021_EN.docx
Analogue displacement sensor (La)
Table 16:
Analogue displacement sensor (La) - parameters
Parameters
Installation location
Connection
Measuring amplifier
Output
Supply voltage
Magnetic inductive sensors (Lk...*)
Table 17:
Magnetic inductive sensors (Lk...*) - parameters
Parameters
Installation location
Connection
Contact
Switching output, max.
Switching voltage, max.
Switching current, max.
Service life, max.
*
Number of signal generators and signal contents:
2
1xSG, lifting rod extended
5
1xSG, lifting rod retracted
7
1xSG, function-dependent intermediate position
3
2xSG, lifting rod extended + lifting rod retracted
4
2xSG, lifting rod extended + function-dependent intermediate position
6
2xSG, lifting rod retracted + function-dependent intermediate position
For detailed information and availability of the respective sensor
version, please contact EMG Automation GmbH.
Functional description
Position indicators
Value/size
Installed internally, observe connection
diagram in terminal box
Terminal board (optional plug connection)
Integrated
4–20 mA
17–30 V DC
Value/size
Installed internally!
Terminal board (optional plug connection)
N/O contact (optionally N/C contact or N/C
contact and N/O contact)
10 W
250 V AC/DC (NC contact only up to 150 V)
0.5 A
10
to 10
circuits
5
6
(depending on load conditions)
4
4.4