10.1
Disconnecting the electrical connections
10.2
Removal
ELHY-Montageanleitung_2021_EN.docx
Disconnecting the electrical connections 10.1
DANGER
Live components
Fatal electric shock or serious burns.
– Work on live components may only be performed by
electricians.
– First disconnect the electrical power supply.
– The earthing conductor must be disconnected after all other
cables.
Observe the allocations in the terminal diagram (⇒Assembly
chapter, Electrical connection section).
First disconnect the electrical power supply.
Disconnect the earthing conductor after all other cables.
CAUTION
Switch-off due to any c springs, brake springs, brake weights
that may be installed or due to other external influences
Risk of crushing due to the lifting rod.
– Before removing the ELHY
must be secured, as the lifting rod retracts automatically.
CAUTION
The ELHY
®
thrusters weigh
between 8 and 45 kg
Risk of injury when lifting the load manually.
– Use suitable lifting equipment (e.g. crane).
– Never remain below suspended loads.
– Use a transport aid (e.g. lifting carriage) with sufficient load
bearing capacity.
Disassembly
®
thrusters, the downstream drive
10
67 / 71