Table 23:
Maintenance log for ELHY
®
ELHY
type
Serial number
System ID
Classification
according to section
3.1 (table 1)
Test object
Cleaning
Test run
Visual checks
Leaks
Bolt connections
Terminal box cover
Cable connections tight
External damage
Functional inspection
Motor functions, running
noises
max. lifting path
Terminal box and cable
infeed leak tightness
Position indicator, signals,
adjustment
Extended test
Actuating force
measurement
Reset force measurement
Power consumption
measurement
Insulation resistance
measurement
Coil resistance
measurement
64 / 71
®
thrusters
Low
Standard
requirements
Test interval according to classification
as required
as required
Every six months
Annually
Annually
Annually
Annually
Annually
Annually
Annually
Annually
Annually
Annually
Annually
Annually
Annually
Annually
Higher
requirements
Test
performed
as required
Every six months
Every six months
Every six months
Every six months
Every six months
Annually
Annually
Annually
Annually
Every 2-3 years
Every 2-3 years
Every 2-3 years
Every 2-3 years
Every 2-3 years