Valor LX2 2200KN Installation Manual page 73

Direct vent zero clearance gas fireplace, 3-sides
Table of Contents

Advertisement

Appendix D - HeatShift
Suggested Con gurations
LX2 Series
Side wall outlets using LDK3
Note - Vertical 6-5/8" venting straight off the
2200 will pass by notched plenum without
offsetting the vent. If using 8" vertical venting,
a 20" deep cavity may not accomodate the
plenum. Adjust cavity depth accordingly.
Front wall outlet using LDK1 or LDK4
Note - When using LDK7, the discharge opening
must be located in the same room as the fireplace.
Not to scale
With LDK7
Installation
®
WARNING
The plenum duct kits are approved
for horizontal discharge ONLY. The
termination duct plates are approved
for vertical upward discharge ONLY. DO
NOT install plenum or termination plates
in oor or ceiling. DO NOT COVER OR
PLACE objects in front of or on top of air
outlet(s). AVOID locating outlet within
7 feet of the oor level as discharge air
temperatures are hot!
D O N O T D I S C H A R G E T H R O U G H
E X T E R I O R W A L L S !
73