Appendix B - Remote Control Operation
Error Codes
In the event of an error condition with the handset or replace, the handset will display an error code.
Failure
Message on
Code
Handset
F04
F04
F06
F06
F07
Low battery
symbol
F09
F09
F46
F46
Duration of
Symptom
Display
4 sec
No pilot ame within 30 sec
Note: after 3 failed ignition
sequences, F06 shown
4 sec
3 failed ignition sequences
in 5 minutes
Fire is not responding, no
pilot ame
Permanent
Battery icon ashes on
handset display
4 sec
Fire is not responding
No electronic control of re
4 sec
Fire is not responding
Intermittent response
No electronic control of re
Possible Cause
No gas supply
Air in pilot supply line
No spark
Reversed polarity in thermocouple wiring
No gas supply
Air in pilot supply line
No spark
Reversed polarity in thermocouple wiring
Incorrect pilot ori ce if valve has been
converted from LPG to NG or vice versa
Low battery in handset
Down arrow button
was not pressed during
pairing
Receiver and handset are not synced
No or bad connection between receiver and
handset
No power at receiver (batteries low)
Low communication range (mains adapter
faulty, handset not communicating with
receiver)