Pressure Testing; Air Shutter Adjustment; Attach The Serial Plate - AGA APRO36AGSS Installation And Service Instructions Manual

36” all gas
Table of Contents

Advertisement

CONVERSION
Check the appliance is electrically safe and gas sound when you have finished.

Pressure Testing

Fig. 8.6
Connect the appliance to the gas supply. Check the appliance
is gas sound.
The gas pressure can be measured at the pressure test point
on the appliance at the right hand, front, cooktop burner.
Remove the burner cap, base and head.
Disconnect from the electricity supply
n
Manually ignite 2 other cooktop burners see "Igniting Cooktop
Burners without Electricity" on page 6. Use a rubber hose
with an inside diameter of ¼" and hold the end of the tube,
tightly, over the orifice.
For proper operation, the pressure of LP supplied to the
regulator must be between 10'' and 13'' of water column
(2.49 - 3.24 kPa).
When checking for proper operation of the regulator, the
inlet pressure must be at least 1'' (0.25 kPa) greater than the
operating (manifold) pressure as given above.
The pressure regulator located at the inlet of the range
manifold must remain in the supply line regardless of
whether natural or LP gas is being used.

Air Shutter Adjustment

The air shutter should be adjusted for LP gas.
Remove the toe kick and remove the 2 screws holding the
orifice bracket (Fig. 8.3). Loosen the locking screw and rotate
the air shutter to the fully open position for LP gas (Fig. 8.6).

Attach the Serial Plate

Record the model and serial number on the conversion serial
plate provided with this kit. The information can be obtained
fro ting plate.
Attach the new plate as close as possible to the existing one.
24