UFO-NT
DPS Parameter
Start teaching
l2
->2 leaf Teaching
Current faults
e®
Delete old errors
O e
Default setting
cp
Standard values
lp
Reset DCU8
pp
3 Menu
DPS Parameter
Hold-open time KB
Os
dyn extension
O D
Manual closing time 05 ... 06 ... 15 ... 25
s6
Back check
D a
Adj.opening angle
e0
Reversing limit
cl
Free swing function
o2
Move towards open
ol
Number of leaves
ef
SI1 contact type
s1
Setting values
Start/terminate
ce
ce
cP
dP
IP
Setting values
00 ... 01 ... 10
12 ... 20
25 ... 50
60
00
no
01
yes
10 ... 12 ... 20 ... 25 ...
50
...
60 ... 80
... 0
...
–9
0
09
00 ...
30
... 90
00
no
01
yes
00
no
01
Obstacle
Motor on
02
Obstacle
Motor off
01
1-leaf Drive
02
2-leaf active
03
2-leaf Passive
00
Not used
02
NC
04
Frequency
Explanation
Teaching a 2-leaf system For the procedure, see chapter 20.2.
Displays the current errors in the fault memory.
Delete with
.
ce
Displays the old errors in the fault memory. Delete with
Reset all the values to the default settings.
The state is the same as after the default setting. Values to
standard setting, fault memory, position and opening angle are
deleted. A teaching run and initialisation run are necessary.
All values are set to the standard setting after acknowledge-
ment. Position and opening angle are retained. Fault memory is
deleted. A teaching run and initialisation run are not necessary.
After acknowledgement the display jumps to 88. Fault memory
is deleted. Position and opening angle are not deleted. The
processor restarts. A teaching run is not necessary, an initialisa-
tion run is necessary.
Explanation
in s;
Hold-open time after activation with KB.
When activated, the passage frequency is taken into account in
the hold-open time. The door does not close as fast when pas-
sage requirements are increased.
in s;
Closing time after manual opening or after automatic opening
with set automatic door closing mode.
Setting pursuant to the table in the Powerturn installation
instructions.
Application of the back check, referenced to maximum opening
range (manual opening).
in degrees;
The value is only for fine adjustment. The value is taught during
the teaching run and then corresponds to point 0. This allows it
to be adjusted manually and, again, subsequently corresponds
to point 0. The opening value can thus be manually adjusted
step-by-step. Is not set in the default setting.
In 0.1 degrees of the drive axle.
Angle on the drive axle to fine-tune the tolerance in the closed
position from which the drive attempts to close again.
Set the value so that the door gap is as small as possible
X
before the drive closes again.
For doors without external loads such as wind or pressure, the
parameter "free swing function" can be activated in order to
enable optimum passage of the door.
In the event of further opening attempts, the drive stops before
the obstacle in the opening range
Drive pushes against the obstacle and turns motor off.
Drive pushes against the obstacle and leaves motor on.
Parameter sets which of the door leaves the drive is installed on.
Parameter sets the use of the safety sensor "close" contact type.
Service menu
.