Procom ML100HBAHR Owner's Operation And Installation Manual page 18

Blue flame vent-free propane/lp gas heater
Table of Contents

Advertisement

The thermostatic control used on these mod-
els differ from standard thermostats. Standard
thermostats simply turn the burner on and off.
The thermostat used on this heater senses
the room temperature. At times the room may
exceed the set temperature. If so, the burner
will shut off. The burner will cycle back on
when room temperature drops below the set
temperature. The control knob can be set to
any comfort level between HI and LO.
Shutting Off Heater
Turn control knob clockwise
OFF position.
1. Remove lower front panel.
2. Follow steps 1 through 5 under Lighting
Instructions, page 16 or 17.
3. With control knob pressed in, strike match.
Hold match to pilot until pilot lights.
18
OPERATION
THERMOSTAT CONTROL OPERATION
ALL MODELS
TO TURN OFF GAS TO APPLIANCE
to the
MANUAL LIGHTING PROCEDURE
www.usaprocom.com
Note: The thermostat sensing bulb measures
the temperature of air near the heater cabinet.
This may not always agree with room tem-
perature (depending on housing construction,
installation location, room size, open air tem-
peratures, etc.) Frequent use of your heater
will let you determine your own comfort levels.
Shutting Off Burner Only
(pilot stays lit)
Turn control knob clockwise
PILOT position.
4. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Follow step 8 under
Lighting Instructions, page 16 or 17.
5. Replace lower front panel.
to the
200052-01B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ml100tbahr

Table of Contents