Procom ML100HBAHR Owner's Operation And Installation Manual page 4

Blue flame vent-free propane/lp gas heater
Table of Contents

Advertisement

1. Do not place Propane/LP supply tank(s)
inside any structure. Propane/LP supply
tank(s) must be placed outdoors.
2. Heaters with a maximum input over
6,000 Btu/Hr shall not be installed in a
bathroom. Heaters with a maximum input
over 10,000 Btu/Hr shall not be installed
in a bedroom.
3. This heater needs fresh air ventilation to
run properly. This heater has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the heater
if not enough fresh air is available. See
Air for Combustion and Ventilation, pages
7 and 8. If heater keeps shutting off, see
Troubleshooting, page 21.
4. Keep all air openings in front and bottom
of heater clear and free of debris. This will
ensure enough air for proper combustion.
5. If heater shuts off, do not relight until you
have provided fresh, outside air. If heater
keeps shutting off, have it serviced.
6. Do not run heater:
• Where flammable liquids or vapors are
used or stored.
• Under dusty conditions.
7. Always run heater with control knob at
PILOT/IGN, LOW or HIGH locked posi-
tions. Never set control knob between
locked positions. Poor combustion and
higher levels of carbon monoxide may
result.
8. Before using furniture polish, wax, carpet
cleaner, or similar products, turn heater off.
If heated, the vapors from these products
may create a white powder residue within
burner box or on adjacent walls or furniture.
9. Do not use heater if any part has been
under water. Immediately call a qualified
service technician to inspect the room
heater and to replace any part of the
control system and any gas control which
has been under water.
4
SAFETY
10. Turn off heater and let cool before servic-
ing. Only a qualified service person should
service and repair heater.
11. Operating heater above elevations of
4,500 feet could cause pilot outage.
12. Install and use heater with care. Follow
all local ordinances and codes. In the ab-
sence of local ordinances and codes, refer
to the Standard for Storage and Handling
of Liquefied Petroleum Gas, ANSI/NFPA
58 Installation Code, CAN/CGAB149.2.
This instructs on the safe storage and
handling of propane/LP gases.
13. This heater may be used in an approved
structure or temporary construction work
enclosure with a remote refillable pro-
pane/LP cylinder ONLY when the cylinder
is located outdoors and the heater is used
with the hose (included with this heater).
NEVER bring a refillable propane/PL
cylinder indoors. A fire or explosion can
occur causing property damage, serious
injury or death.
14. Use only the hose and factory preset
regulator provided with the heater, when
connecting to portable supply gas tank.
Use only replacement pressure regula-
tors and hose assemblies specified in this
manual.
15. Inspect the hose before each use of the
heater. If it is evident there is excessive
abrasion or wear or the hose is cut, it must
be replaced prior to the heater being put
into operation.
16. Use only propane gas set up for vapor
withdrawal.
www.usaprocom.com
200052-01B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ml100tbahr

Table of Contents