Advertisement

OWNER ' S OPERATION AND INSTALLATION MANUAL
ML100HBAHR & ML100TBAHR

Table of Contents

Important Safety Information....................................2
Product Features.....................................................3
Air For Combustion& Ventilation .................................4
Installation................................................................6
Operating Your Heater............................................13
Care & Maintenance...............................................14
Troubleshooting......................................................15
Specifications..........................................................18
Parts List..................................................................20
WARNING:
This is an unvented gas-
fired heater. It uses air (oxygen) f r o m
t h e
r o o m
i n
Provisions for adequate combustion and
ventilation air must b e p r o v i d e d . R e f e r
t o A i r F o r Combustion and Ventilation
section on page 4 of this manual.
WARNING: If the information in this
manual is not followed exactly, a fi r e o r
e x p l o s i o n m a y r e s u l t causing property
damage, personal injury, or loss of life.
Installer: Please leave these instructions with
the consumer.
Consumer: Please retain these instructions for
future use.
Questions about installation, operation, or troubleshooting? Before returning to your retailer, contact our
customer service department at (877)-886-5989,
w h i c h
i t
i s installed.
BLUE FLAME VENT-FREE
PROPANE/PL GAS HEATER
Do not store, or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
 Do not try to light any appliance.
D o not touch any electrical switch;
use any phone in your building.
 Immediately
call
neighbor's
phone.
instructions.
 If
you
cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by a
qualified
installer, service
supplier.
WARNING: Improper
ment, alteration, service or maintenance can
cause injury or property damage. Refer to this
manual for correct installation and operational
procedures. For assistance or additional
information consult a qualified installer, service
agency, or gas supplier.
This appliance may be installed in an after-
market* permanently located, manufactured
(mobile) home, where not prohibited by lo-
cal codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases.
*Aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
do
your gas supplier from a
Follow
the
gas supplier's
agency or gas
installation, adjust-
PC-ML062-16HR-1202
not
R

Advertisement

Table of Contents
loading

Summary of Contents for Procom ML100HBAHR

  • Page 1: Table Of Contents

    Installation and service must be performed by a qualified installer, service agency or gas supplier. ML100HBAHR & ML100TBAHR Table of Contents WARNING: Improper installation, adjust- ment, alteration, service or maintenance can Important Safety Information........2 cause injury or property damage. Refer to this Product Features.............3...
  • Page 2: Important Safety Information

    WARNING knob at PILOT/IGN, LOW or disease or anemia, those under HIGH locked positions. Never Models ML100HBAHR, ML100TBAHR the influence of alcohol, and those set control knob between locked are equipped for propane gas. Field at high altitudes.
  • Page 3: Product Features

    PRODUCT FEATURES 15. This heater may be used in a recreational enclosure or temporary construction work enclosure with a remote refillable propane/PL cylinder ONLY when the cylinder is located outdoors and the heater is used with the hose (included with this heater). NEVER bring a refillable propane/PL cylinder indoors.
  • Page 4: Air For Combustion& Ventilation

    Unusually Tight Construction Confined and FRESH AIR FOR The air that leaks around doors Unconfined Space COMBUSTION AND and windows may provide enough Confined space is a space whose VENTILATION fresh air for combustion and ventilation. volume is less than 50 cubic feet However, in buildings of unusually per 1,000 Btu per hour (4.8 m tight construction, you must provide...
  • Page 5: Air For Combustion And Ventilation

    3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Example: Gas water heater* Btu/Hr Gas water heater 44,000 Btu/Hr Gas furnace Btu/Hr Vent free heater 10,000 Btu/Hr Vented gas heater Btu/Hr total 54,000 Btu/Hr Gas Fireplace logs Btu/Hr Other gas appliances* +...
  • Page 6: Installation

    Ventilation Air From Outdoors Provide extra fresh air by using venti- lation grills or ducts: You must pro- vi de two pe rm an e nt o pe n ing s: o ne ” within 12 of the ceiling and one within ”...
  • Page 7 INSTALLATION Attaching to Wall Stud: This FASTENING HEATER TO WALL WA R N I N G : M a i n t a i n t h e method provides the strongest hold. Mounting Bracket minimum clearances shown Insert mounting screws through The mounting bracket is located F i g u r e 4 .
  • Page 8 INSTALLATION IMPORTANT: Do not Attaching Mounting Bracket To hammer key! For thick walls Wall ” (over 1/2 thick) or solid walls, Note: Wall anchors, mounting do not pop open wings. screws, and spacers are in hardware package. The hardware package is provided with heater.
  • Page 9 INSTALLATION Continued 1. Remove gas fitting from 6. Connect hose to heater inlet. CONNECTING TO PORTABLE CYLINDER GAS SUPPLY hardware bag. Tighten firmly using a wrench. 2. Apply pipe joint sealant lightly to You must use the regulator WARNING: Review and understand male NPT threads (see Figure the warnings in the Safety Information supplied with heater.
  • Page 10 INSTALLATION CONNECTING TO PERMANENTLY LOCATED 100# OR LARGERGAS SUPPLY WARNING: A qualified service person must connect heater to gas supply. Follow all local codes. WARNING: This appliance ” requires a 3/8 NPT (National Pipe Thread) inlet connection to the pressure regulator. WARNING: Never con- nect heater private (non-utility) gas well.
  • Page 11: Operating Your Heater

    INSTALLATION OPERATING YOUR HEATER CHECKING GAS Pressure Testing Heater Gas NON-THERMOSTAT MODEL CONNECTIONS Connections   FOR YOUR SAFETY 1. Open equipment shutoff valve WARNING: Test all gas piping READ BEFORE LIGHTING (see Figure 15). and connections for leaks after 2.
  • Page 12 OPERATING YOUR HEATER ML100HBAHR Manual Control Models • Set control knob to desired   LIGHTING   TO TURN OFF heating position. INSTRUCTIONS GAS TO APPLIANCE NOTE: Both HIGH and LOW are STOP! Read safety locked positions. You must press...
  • Page 13: Operating Your Heater

    OPERATING YOUR HEATER ML100TBAHR 4. Wait five(5) minutes to clear CAUTION: Do not try to THERMOSTAT MODEL out any gas. Then smell for gas, adjust heating levels by using the including near the floor. If you   FOR YOUR SAFETY “...
  • Page 14: Care & Maintenance

    OPERATING HEATER Continued BURNER FLAME PATTERN ODS/PILOT AND BURNER Figure 23 shows a correct burner Use a vacuum cleaner, pres-    MANUAL LIGHTING flame pattern. Figure 24 shows an surized air. PROCEDURE incorrect burner flame pattern. Remove lower front panel (see If burner flame pattern is incorect, as CLEANING BURNER Figure 7 page 7).
  • Page 15: Troubleshooting

    TROUBLESHOOTING Note : troubleshooting WARNING: Only a qualified CAUTION: Never use a items are listed in order of service person should service and wire, needle, or similar object to operation. repair heater. clean ODS/pilot. This can damage ODS/pilot unit. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed...
  • Page 16 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY B u r n e r ( s ) d o e s n o t l i g h t a f t e r 1 Burner orifice is clogged. 1. Clean burner orifice (see Cleaning ODS/pilot is lit.
  • Page 17 TROUBLESHOOTING Continued WARNING: If you smell gas  Shut off gas supply.  Do not try to light any appliance.  Do not touch any electrical switch; do not use any phone in your building.  Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • Page 18: Specifications

    SPECIFICATIONS ML100HBAHR ML100TBAHR Btu(available) 5,500/10,000 10,000 Gas Type Propane/PL Only Propane/PL Only Ignition Piezo Piezo Pressure Regulator setting ” ” W.C. W.C. Inlet Gas Pressure* (inches of water) Maximum ” ” Minimum ” ” Dimensions, Inches (HxWxD) Heater × ×...
  • Page 19 ILLUSTRATED PARTS BREAKDOWN ML100HBAHR...
  • Page 20: Parts List

    PARTS LIST This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page18 of this manual. ML100HBAHR PART NO. DESCRIPTION QTY. MB10008 Cabinet Assembly MB09003 Lower Front Panel Assembly MB11005...
  • Page 21 ILLUSTRATED PARTS BREAKDOWN ML100TBAHR...
  • Page 22 PARTS LIST This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 18 of this manual. ML100TBAHR PART NO. DESCRIPTION QTY. MB10007 Cabinet Assembly MB09003 Lower Front Panel Assembly MB11005 Reflector Unit ML086-03...
  • Page 23: Warranty Information

    WARRANTY INFORMATION Keep This Warranty IMPORTANT: We urge you to fill your warranty registration card within TEN(10) days of date of installation, complete with the entire serial number which can be found on the rating plate. Retain this portion of the card for your record. Always specify model and serial numbers when communicating with customer service.

This manual is also suitable for:

Ml100tbahr

Table of Contents