Procom ML100HBAHR Owner's Operation And Installation Manual

Procom ML100HBAHR Owner's Operation And Installation Manual

Blue flame vent-free propane/lp gas heater

Advertisement

Quick Links

OWNER ' S OPERATION AND INSTALLATION MANUAL
ML100HBAHR & ML100TBAHR

Table of Contents

Important Safety Information........................................2
Product Features...........................................................3
Installation......................................................................6
Operating Your Heater................................................13
Cleaning & Maintenance............................................14
Trouble Shooting.........................................................15
Specifications................................................................18
Parts List.......................................................................20
WARNING: This is an unvented gas-fired
heater. It uses air (oxygen) f r o m t h e r o o m i n
w h i c h i t i s installed. Provisions for adequate
combustion and ventilation air must be pr ovided.
R e f e r t o A i r F o r Combustion and Ventilation
section on page 4 of this manual.
WARNING: If the information in this manual
is not followed exactly, a f i r e o r e x p l o s i o n
m ay r e su lt causing property damage,
personal injury, or loss of life.
TOLL FREE NUMBER: 1-877-886-5989
BLUE FLAME VENT-FREE
PROPANE/LP GAS HEATER
Do not store, or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
l Do not try to light any appliance.
l Do not touch any electrical switch; do not
use any phone in your building.
l Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
l
If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by a
qualified installer, service agency or gas
supplier.
WARNING:
Improper installation, adjustment,
alteration, service or maintenance can cause
injury or property damage. Refer to this manual
for correct installation and operational procedures.
For assistance or additional information
consult a qualified installer, service agency,
or gas supplier.
This appliance may be installed in an aftermar-
ket*
permanently
(mobile) home, where not prohibited by local
codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This
appliance is not convertible for use with other
gases.
*Aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
Installer: Please leave these instructions with the
consumer.
Consumer: Please retain these instructions for
future use.
located, manufactured
PC-ML062-16HR-1004

Advertisement

Table of Contents
loading

Summary of Contents for Procom ML100HBAHR

  • Page 1: Table Of Contents

    Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call ML100HBAHR & ML100TBAHR the fire department. Installation and service must be performed by a Table of Contents qualified installer, service agency or gas supplier.
  • Page 2: Important Safety Information

    WARNING 10. Always run heater with control disease or anemia, those under the knob at PILOT/IGN, LOW or Models ML100HBAHR, HIGH locked positions. Never influence of alcohol, and those ML100TBAHR are equipped for set control knob between locked propane gas.
  • Page 3: Product Features

    PRODUCT FEATURES 15. This heater may be used in a recreational enclosure or temporary construction work enclosure with a remote refillable propane/LP cylinder ONLY when the cylinder is located outdoors and the heater is used with the hose (included with this heater). NEVER bring a refillable propane/LP cylinder indoors.
  • Page 4: Air For Combustion And Ventilation

    Confined and Unusually Tight Construction AIR FOR COMBUSTION The air that leaks around doors and Unconfined Space AND VENTILATION windows may provide enough fresh The National Fuel Gas Code air for combustion and ventilation. ANS Z223.1 defines a confined However, in buildings of unusually space as a space whose volume WARNING: This heater tight construction, you must provide...
  • Page 5 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Gas water heater* Btu/Hr Example: Gas furnace Btu/Hr Gas water heater 44,000 Btu/Hr Vented gas heater Btu/Hr Vent free heater 10,000 Btu/Hr Gas Fireplace logs Btu/Hr Total 54,000...
  • Page 6: Installation

    Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts: You must provide two permanent openings: one " within 12 of the ceiling and one within " of the floor. Connect these items directly to the outdoors or spaces open to the outdoors.
  • Page 7 INSTALLATION FASTENING HEATER TO WALL Attaching to Wall Stud: This method WARNING: Maintain the Mounting Bracket provides the strongest hold. Insert minimum clearances shown The mounting bracket is located mounting screws through mounting F i g u r e 4 . y o u c a n , back panel of heater (see bracket and into wall studs.
  • Page 8 INSTALLATION Attaching Mounting Bracket To IMPORTANT: Do not Wall hammer key! For thick walls Note: Wall anchors, mounting " (over 1/2 thick) or solid walls, screws, and spacers are in do not pop open wings. hardware package. The hardware package is provided with heater. Attaching to Wall Stud Method Figure 12 - Installing Bottom For attaching mounting bracket to...
  • Page 9 INSTALLATION Continued CONNECTING TO PORTABLE 1. Remove gas fitting from 6. Connect hose to heater inlet. CYLINDER GAS SUPPLY hardware bag. Tighten firmly using a wrench. 2. Apply pipe joint sealant lightly to You must use the regulator male NPT threads (see Figure WARNING: Review and understand supplied with heater.
  • Page 10 INSTALLATION CONNECTING TO PERMANENTLY LOCATED 100# OR LARGER GAS SUPPLY WARNING: A qualified service person must connect heater to gas supply. Follow all local codes. WARNING: This appliance r equi r es a 3/ 8" NPT (National Pipe T h r e a d ) i n l e t c o n n e c t i o n to the pressure regulator.
  • Page 11 INSTALLATION OPERATING YOUR HEATER CHECKING GAS Pressure Testing Heater Gas NON-THERMOSTAT MODEL CONNECTIONS Connections 1. Open equipment shutoff valve FOR YOUR SAFETY Test all gas piping WARNING: (see Figure 15). READ BEFORE LIGHTING and connections for leaks after Open propane/LP supply tank installing or servicing.
  • Page 12 OPERATING YOUR HEATER ML100HBAHR Manual Control Models l Set control knob to desired LIGHTING TO TURN OFFn heating position. INSTRUCTIONS GAS TO APPLIANCE NOTE: Both HIGH and LOW are STOP! Read safety locked positions. You must press Shutting Off Heater...
  • Page 13: Operating Your Heater

    OPERATING YOUR HEATER ML100TBAHR THERMOSTAT MODEL Wait five(5) minutes to clear CAUTION: Do not try to out any gas. Then smell for gas, FOR YOUR SAFETY adjust heating levels by using the including near the floor. If you READ BEFORE LIGHTING equipment shutoff valve.
  • Page 14: Cleaning & Maintenance

    OPERATING HEATER BURNER FLAME PATTERN ODS/PILOT AND BURNER OR Continued Figure 23 shows a correct burner Use a vacuum cleaner, pres- flame pattern. Figure 24 shows an MANUAL LIGHTING surized air. incorrect burner flame pattern. If PROCEDURE pilot flame pattern is incorrect, as Remove lower front panel (see shown in Figure 24.
  • Page 15: Troubleshooting

    TROUBLESHOOTING Note : troubleshooting WARNING: Only a qualified CAUTION: Never use a wire, items are listed in order of needle, or similar object to clean service person should service and operation. ODS/pilot. This can damage repair heater. ODS/pilot unit. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed in,...
  • Page 16 TROUBLESHOOTING Continued POSSIBLE CAUSE REMEDY OBSERVED PROBLEM 1. Burner orifice is clogged. 1. Clean burner orifice (see Cleaning Burne r ( s ) d o e s n ot l i g h t after and Maintenance Page 14) or ODS/pilot is lit.
  • Page 17 TROUBLESHOOTING Continued WARNING: If you smell gas Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • Page 18: Specifications

    SPECIFICATIONS ML100HBAHR ML100TBAHR Btu(available) 5,500/10,000 10,000 Gas Type Propane/LP Only Propane/LP Only Ignition Piezo Piezo " " Pressure Regulator setting W.C. W.C. Inlet Gas Pressure *(inches of water) " " Maximum " " Minimum Dimensions, Inches (HxWxD) × × Heater...
  • Page 19 ILLUSTRATED PARTS BREAKDOWN ML100HBAHR...
  • Page 20: Parts List

    PARTS LIST This list contains replaceable parts for your heater. When ordering replace- ment parts, follow the instructions listed under Replacement Parts on page 18 ML100HBAHR of this manual. ML100HBAHR DESCRIPTION QTY. PART NO MB09003 Lower Front Panel Assembly ML086-03...
  • Page 21 ILLUSTRATED PARTS BREAKDOWN ML100TBAHR...
  • Page 22 PARTS LIST This list contains replaceable parts for your heater. When ordering replace- ML100TBAHR ment parts, follow the instructions listed under Replacement Parts on page 18 of this manual. ML100TBAHR DESCRIPTION QTY. PART NO MB09003 Lower Front Panel Assembly ML086-03 Glass ML087-03 Upper Glass Retainer...

This manual is also suitable for:

Ml100tbahr

Table of Contents