CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
1. STOP! Read the safety information on
page 16.
2. Make sure equipment shutoff valve is fully
open.
3. Turn control knob clockwise
OFF position.
4. Wait five (5) minutes to clear out any air.
Then smell for gas, including near the
floor. If you smell gas, STOP! Follow "B"
in the safety information, page 16. If you
do not smell gas, go to the next step.
5. Turn control knob counterclockwise
to the PILOT position. Press in control
knob for five (5) seconds.
Note: The first time that the heater is oper-
ated after connecting the gas supply,the
control knob should be pressed for about
thirty (30) seconds. This will allow air to
bleed from the gas system. If pilot does
not stay lit, refer to Troubleshooting, pages
21 though 23. Also contact a qualified
service technician or gas supplier for
repairs. Until repairs are made, light pilot
with match.
• If control knob does not pop up when
released, contact a qualified service
technician or gas supplier for repairs.
6. With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached to
the front of burner. The pilot can be
seen through the grill. If needed, keep
pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, refer to
Troubleshooting, pages 21 though 23.
200052-01B
OPERATION
THERMOSTAT MODEL ML100TBAHR
LIGHTING INSTRUCTIONS
to the
www.usaprocom.com
Ignitor Electrode
Thermocouple
Figure 20 - Pilot
Also contact a qualified service technician
or gas supplier for repairs. Until repairs
are made, light pilot with match. To light
pilot with match, see Manual Lighting
Procedure, page 18.
7. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. If control
knob does not pop up when released,
contact a qualified service technician or
gas supplier for repairs.
Note: If pilot goes out, repeat steps 3
through 7. This heater has a safety inter-
lock system. Wait one (1) minute before
lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The main burner
should light. Set control knob to any heat
level between HI and LO.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
Ignitor Button
Figure 21 - Control Knob in the OFF
Position
Pilot Burner
Control Knob
17