Installing Bottom Mounting Bracket
1. Install bottom bracket to heater bottom
with two screws. It may be more conve-
nient to remove heater from wall bracket
to attach.
2. Place heater on wall mounting bracket.
3. Mark screw locations on wall.
4. Remove heater from mounting bracket.
5. If installing bottom mounting screws into
hollow or solid wall, install wall anchors.
Follow steps 1 through 4 under Attaching
To Wall Anchor Method, page 11. If install-
ing bottom mounting screw into wall stud,
drill holes at marked locations using 9/64"
drill bit.
6. Replace heater onto mounting bracket.
7. Place spacers between bottom mounting
holes and wall anchor or drilled hole.
8. Hold spacer in place with one hand. With
other hand, insert mounting screw though
bottom mounting hole and spacer. Place
tip of screw in opening of wall anchor or
drilled hole.
CONNECTING TO PORTABLE CYLINDER GAS SUPPLY
WARNING: Review and un-
derstand the warnings in the
Safety section, page 3. They are
needed to safely operate this
heater. Follow all local codes
when using this heater.
WARNING: Test all gas piping
and connections for leaks after
installation or servicing. Never
use an open flame to check for
a leak. Apply a noncorrosive
leak detection fluid to all joints.
Bubbles forming show a leak.
Correct all leaks at once.
WARNING: Use pipe joint
sealant that is resistant to liquid
petroleum (LP) gas.
12
INSTALLATION
9. Tighten both screws until heater is firmly
secured to wall. Do not over tighten.
Note: Do not replace front panel at this time.
Replace front panel after making gas connec-
tions and checking for leaks.
Figure 12 - Installing Bottom Mounting
Never bring a refillable propane/
LP cylinder indoors. A fire or
explosion can occur causing
property damage, serious injury
or death.
requires a 3/8" NPT (National
Pipe Thread) inlet connection to
the pressure regulator.
vice technician must connect
heater to gas supply. Follow all
local codes.
IMPORTANT: You must use a propane/LP
gas supply cylinder that is compatible with
the connection device provided with the hose
and regulator.