6.4.1 Checking line voltage
From the offline menu, select AC and press enter. The display alternates
between L2 and the present rms voltage found on the phase two supply to
the rack, eg 220.
a)
To exit, press enter. The display returns to the AC menu header,
press
or
6.4.2 Setting the output voltage scale
For a full explanation of this function, see section 6.5.2
a)
From the offline menu, Select CAL, and press enter. The display
shows the present rms voltage set for 100% dimmer output, eg 220.
b)
Use the
and
steps of one volt.
c)
Press enter to save the new value and exit to the offline menu.
6.4.3 Clearing configuration settings
a)
From the offline menu, select CLr, then press enter, to clear all
address, profile, speed and output voltage scale settings back to fac-
tory defaults.
, until the offline menu header – – – appears.
keys to change the rms voltage output scale, in