Overview
The Unison Echo Forward-Phase Dimmer–Gen 2 provides control for individual
fixtures or zone power for 120 V and 277 V line voltage loads that require
forward-phase dimming, up to 600 watts. The Forward-Phase Dimmer–Gen 2
is compatible with all Echo control products, including daylight and
occupancy/vacancy sensors and manual control stations on the EchoConnect
control bus.
The Forward-Phase Dimmer–Gen 2 controls lighting loads based on the
following:
Preset and Zone controls received from connected Echo control
stations
Ambient light levels as monitored by Echo Light Sensors
Occupancy state as monitored by Echo Occupancy/Vacancy Sensors
Input from other Echo control devices
Corpora te He a dqua rte rs Middleton, WI, USA +1 608 831 4116
London, UK +44 (0)20 8896 1000 Holzk irc he n, DE +49 (80 24) 47 00-0
Rome , IT +39 (06) 32 111 683 Hong Kong +852 2799 1220 P a ris, FR +33 1 4243 3535
We b
etcconnect.com
Conta c t
etcconnect.com/contactETC
Product information and specifications subject to change. ETC intends this document
to be provided in its entirety. Trademark and patent
7 1 8 7 M 2 1 0 5 Rev A Released 2019-12
Support
support.etcconnect.com
© 2019 Electronic Theatre Controls, Inc.
120 VAC
model shown
info: etcconnect.com/ip

Advertisement

Table of Contents
loading

Summary of Contents for ETC Unison Echo Forward-Phase Dimmer-Gen 2

  • Page 1 Conta c t etcconnect.com/contactETC © 2019 Electronic Theatre Controls, Inc. Product information and specifications subject to change. ETC intends this document to be provided in its entirety. Trademark and patent info: etcconnect.com/ip 7 1 8 7 M 2 1 0 5 Rev A Released 2019-12...
  • Page 2: Custom Configuration

    See the Echo Inspire Station Installation Guide , Echo Occupancy/Vacancy Sensor Installation Guide , or Echo Light Sensor Installation Guide for more information about how to set levels and controls. You can download ETC manuals free of charge from the ETC website (see page 1).
  • Page 3: Specifications

    ETC Installation Guide Forward-Phase Dimmer–Gen 2 Specifications For use with ETC dimming and relay products. Ambient Environment For indoor use only. Rated for plenum use. Electrical Specification Two models are available: 120 VAC, +/- 10% at 60 Hz, maximum load 600 W (5 A) •...
  • Page 4: Prepare For Installation

    The Forward-Phase Dimmer–Gen 2 connects to the EchoConnect station communication bus for control. EchoConnect is a bidirectional protocol that uses one pair of wires (data + and data -) for both data and power. ETC recommends using Belden 8471 (or approved equal) Class 2 wire. The total combined length of an EchoConnect wire run (using Belden 8471, or equal) may not exceed 500 m (1,640 ft).
  • Page 5: Installation

    ETC Installation Guide Forward-Phase Dimmer–Gen 2 Installation Installation should follow all local codes and standard electrical practices. Ensure that the junction box is clean and free of obstructions and that all wiring is installed correctly. WARNING: Risk of electric shock! This device utilizes high voltage and should only be installed by a qualified installer or electrician.
  • Page 6 ETC Installation Guide Forward-Phase Dimmer–Gen 2 Connect EchoConnect The EchoConnect wire terminations are bound together and include a black wire (data -), a white wire (data +), and a green/yellow wire (ESD). Because EchoConnect is topology free, you can install the wires in any combination of bus, star, loop, or home-run.
  • Page 7 ETC Installation Guide Forward-Phase Dimmer–Gen 2 Connect Power Input and Dimmer Output The power input wiring exits the Forward-Phase Dimmer–Gen 2 through the knockout mount on the enclosure. Connect the power input wiring. The dimmer is supplied with inputs specific to the input voltage, either 120 VAC or 277 VAC.
  • Page 8: Power Up And Test

    ETC Installation Guide Forward-Phase Dimmer–Gen 2 Assign Zones and Spaces You can assign zones and spaces using the two rotary switches on the side panel of the controller. By default, these switches are set to Zone 1, Space 1. Control inputs from the...
  • Page 9 ETC Installation Guide Forward-Phase Dimmer–Gen 2 Set the Dimming Mode Use the Dim Mode button to manually set the dimming mode or to enter Fluorescent Voltage Adjustment mode. The related LED indicates which mode is currently active. Press the Dim Mode button to toggle the dimming mode: Linear: The linear curve matches the control input percentage to Root •...
  • Page 10: Troubleshooting

    ETC Installation Guide Forward-Phase Dimmer–Gen 2 Fluorescent Voltage Adjustment Mode This mode adjusts the minimum turn-on voltage used by Fluorescent dimming mode. Press and hold the Dim Mode button for 5 seconds to enter Fluorescent Voltage Adjustment mode. The LED is amber when this mode is active.
  • Page 11: Update Firmware

    Forward-Phase Dimmer–Gen 2 Update Firmware If updated firmware is required, you can update the firmware on the Forward- Phase Dimmer–Gen 2 by using ETC UpdaterAtor software and a microSD card. You can download UpdaterAtor from the ETC website at etcconnect.com , or you can access UpdaterAtor from Concert software.
  • Page 12 ETC Installation Guide Forward-Phase Dimmer–Gen 2 Forward-Phase Dimmer–Gen 2 Page 12 of 12...

Table of Contents