Address Setting; Dimmer Mode; Testing Dimmers At Levels - ETC SMARTRACK User Manual

Table of Contents

Advertisement

Version 1.2

6.2. Address setting

Once accessed, the control panel may be used to set a new starting address for
the rack. Note that all dimmers will automatically be numbered in ascending
sequence, starting with the top left dimmer in the rack.
a) Use the
the enter LED flashes, to indicate that the displayed start address is not that
recorded in memory. By holding down either of the
selected address will automatically increment or decrement. The longer the
key is held, the greater the rate of change of the address.
b) Confirm the new start address by pressing enter. The enter LED stops flash-
ing, indicating that the new address has been recorded.

6.3. Dimmer mode

In dimmer mode you can:
test dimmers at levels
set dimmer profiles
set dimmer response speeds
Having accessed the control panel, press dimmer to enter dimmer mode. The
dimmer LED is now lit.
In dimmer mode, when using the
range of dimmer numbers displayed to the dimmers in the rack, plus ALL, where
all dimmers in the rack may be tested, or have profile and speed settings
changed.
ALL dimmers are selected when the dimmer display is taken out of range, in
either direction, using the
press
to select ALL dimmers.

6.3.1 Testing dimmers at levels

Once in dimmer mode, select all or any dimmers. Now use the rotary
potentiometer to raise the selected dimmer(s) to a level.
and
keys to select a new start address for the rack. Note that
and
and
keys. So, having entered dimmer mode, just
and
keys, the
keys, note that Smartrack limits the
Smartrack User Manual
page 43

Advertisement

Table of Contents
loading

Table of Contents