We recommend using a large cable duct running across the top of a bank of
Smartracks, carrying power and load wiring. Alternatively, power wires may be
run in from below, and load wires from above, or vice versa.
Note that DMX signal wires should be run in separate cableways from the power
and load cables, outside the racks, though it is permissible to mix them in the
immediate vicinity and inside the racks themselves.

4.2.1 Marking out a wall

Use the dimensions below to mark out a grid on the wall where the
Smartracks are to be installed. Note the height and width of the racks and
the mounting centres:
Two stacks of three
Smartracks, showing posi-
tions of fixing holes. 13mm
has been allowed for the
feet at the bottom of each
stack, which are optional.
90
90
Rack:
h 650mm,
w 850mm
Mounting centres:
h 560mm,
58
w 760mm
850
45
760
Stack 1
Smartrack User Manual
850
760
Stack 2