6.3 DC Side Connection

For Omniksol-1k-TL2, Omniksol-1.5k-TL2, Omniksol-2k-TL2, Omniksol-2.5k-TL2-M
and Omniksol-3k-TL2-M, there is one MPP Tracker, and the DC characteristics of
them are illustrated as the following table.
Inverter Type
Omniksol-1k-TL2
Omniksol-1.5k-TL2
Omniksol-2k-TL2
Omniksol-2.5k-TL2-M
Omniksol-3k-TL2-M
MC4 Assembly instructions
If, during self assembly, parts and tools other than those stated by MC are used
or if the preparation and assembly instructions described here are disregarded then
neither safety nor compliance with the technical data can be guaranteed.
For protection against electric shock, PV-connectors must be isolated from the
power supply while being assembled or disassembled.
The end product must provide protection from electric shock.
26
DANGER
DANGER to life due to potential fire or electricity shock.
NEVER connect or disconnect the connectors under load.
NOTICE
DC Switch (Optional) may be integrated or external to
Inverter, and it can be used to connect or disconnect the
DC source from Inverter.
MPP
Tracker
1
Max.
Max.
DC Power
DC Voltage
1300W
1750W
2300W
500V
2800W
3250w
Max.
DC Current
16A
18A
18A
18A
18A