Dc Side Connection - Omnik Omniksol-3k-TL2 User Manual

Table of Contents

Advertisement

6.3 DC Side Connection

For Omniksol-3k-TL2, Omniksol-4k-TL2 and Omniksol-5k-TL2, there are two MPP
Trackers, and the DC characteristics of them are illustrated as the following table.
Inverter Type
Omniksol-3k-TL2
Omniksol-4k-TL2
Omniksol-5k-TL2
MC4 Assembly instructions
If, during self assembly, parts and tools other than those stated by MC are used
or if the preparation and assembly instructions described here are disregarded then
neither safety nor compliance with the technical data can be guaranteed.
For protection against electric shock, PV-connectors must be isolated from the
power supply while being assembled or disassembled.
The end product must provide protection from electric shock.
The use of PVC cables is not recommended.
Unplugging under load: PV plug connections must not be unplugged while under
load. They can be placed in a no load state by switching off the DC/AC converter or
breaking the DC circuit interrupter. Plugging and unplugging while under voltage is
permitted.
24
DANGER
DANGER to life due to potential fire or electricity shock.
NEVER connect or disconnect the connectors under load.
NOTICE
DC Switch (Optional) may be integrated or external to
Inverter, and it can be used to connect or disconnect the
DC source from Inverter.
MPP Tracker
2
Max.
Max.
DC Power
DC Voltage
3400W
4600W
590V
5200W
Max.
DC Current
12*2A
16*2A
18*2A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omniksol-4k-tl2Omniksol-5k-tl2