The use of PVC cables is not recommended.
Unplugging under load: PV plug connections must not be unplugged while under
load. They can be placed in a no load state by switching off the DC/AC converter or
breaking the DC circuit interrupter. Plugging and unplugging while under voltage is
permitted.
It is unadvisable to use non-tinned cables of type H07RN-F, since with oxidized
copper wires the contact resistances of the crimp connection may exceed the permitted
limits.
Disconnected connectors should be protected from dirt and water with sealing
caps.
Plugged parts are watertight IP67. They cannot be used permanently under
water. Do not lay the MC-PV connectors on the roof surface.
See the MC catalogue 2 solar lines for technical data and assembled parts.
PV-Female cable coupler
PV-KBT4
Touch
protection,
mated/unmated
Ambient
temperature
range
Upper limiting
temperature
Note: The DC connector is MC4 type; you can order the specified tools at MC website:
http://www.multi-contact.com.
PV-Male cable coupler
IP67/IP2X
-40° to 90° C (IEC/CEI)
-40° to 75° C(UL)
-40° ...70° C (UL:14AWG)
105° C (IEC/CEI)
Tools required
(ill. 1)
Stripping pliers PV-AZM... incl. built-in blade as well as
hexagonal screwdriver A/F 2,5mm.
Cable cross section: 1,5 / 2,5 / 4 / 6 mm²
Type: PV-AZM-1.5/6
Order No. 32.6029-156
PV-KST4
17A(1,5mm
Rated
22A(2,5mm
current
30A(4mm
Rated
1000V (IEC/CEI)
600V (UL)
voltage
Safety class
II
Optional
PV-SSH4
2
/16AWG)
2
/14AWG)
2
2
,6mm
/10AWG)
27