6.3

DC Side Connection

For Omniksol-1k/1.5k-TL-M, there is only one MPP Tracker, and the DC characteristics
of them are illustrated as the following table.
Inverter Type
Omniksol-1k-TL-M
Omniksol-1.5k-TL-M
MC4 Assembly instructions
If, during self assembly, parts and tools other than those stated by MC are used or
if the preparation and assembly instructions described here are disregarded then neither
safety nor compliance with the technical data can be guaranteed.
For protection against electric shock, PV-connectors must be isolated from the
power supply while being assembled or disassembled.
The end product must provide protection from electric shock.
The use of PVC cables is not recommended.
Unplugging under load: PV plug connections must not be unplugged while under
load. They can be placed in a no load state by switching off the DC/AC converter or
DANGER
DANGER to life due to potential fire or electricity shock.
NEVER connect or disconnect the connectors under load.
NOTICE
DC Switch (Optional) may be integrated or external to
Inverter, and it can be used to connect or disconnect the DC
source from Inverter.
MPP
Tracker
1
Max. DC
Max. DC
Power
Voltage
1250W
1500W
Max. DC
Current
200V
10A
250V
10A