MANURE CONTROL

Analog Signal (External VFD Only)

9.3.7
Use for controlling and monitoring external VFD. Only appear when motor is set to External VFD
(See section 9.3.1.2)
Address of Analog Input for Current Signal: PLC analog input address associated with the VFD
current output.
Address of Analog Output to Send Speed Signal: PLC analog output address associated with the
VFD reference speed input.

Shutdown ON Separator Doors Opening

9.3.8
You have the option to do a progressive stop if the diaphragm switch coming from a screw is
activated.
equipment is at slow speed (VFD only) or stay on when the hopper hit.
Delay After Shutdown (sec): Time that the equipment is at slow speed (VFD only) or stay off
when the hopper clear.
Speed Before/After Shutdown (VFD): VFD reference speed (%) for slow down speed.
Example: If the hopper is activated, I want the pump to slow down at 80% for 60s before
stopping. If the hopper cleared, I want to drive to stay at slow down speed for another 30 before
going full speed. The vibrator must be ON if the pump is started.
Here a graphical representation of the setup:
TECHNICAN'S MANUAL V0.3
2020-02-19
Screw 1: Select the first
screw that is associated
with the equipment you
are programming
Screw 2: Select the second
screw that is associated
with the equipment you
are programming
Delay Before Shutdown
(sec):
Time
that
the
32