MANURE CONTROL

Output

9.3.2
The Output parameter is depending on motor type (See Section 9.3.1)
9.3.2.1 Alternative Mode
If the Alternative Mode is enabled, the system alternates between the
two programmed output on an equipment start command.
9.3.2.2 Contactor and External VFD mode
Those parameters are true only if the motor type is set to Contactor or External VFD.
Standard:
Alternative:
9.3.2.3 VFD and Softstart
Those parameters are true only if the motor type is set to VFD or Softstart.
Standard:
Alternative:
TECHNICAN'S MANUAL V0.3
Address: PLC digital output address (See
Section 5) to activate equipment. Enter
address in Output 2 if the alternative
mode is activated.
Node: Communication address for smart
overload. Enter address in Output 2:
Node if the alternative mode is activated.
Address: Last 3 digit of the assign IP
address (192.168.10.xxx).
Output 1 Contactor: PLC digital output
address (See Section 5) to activate motor
1.
Output 2 Contactor: PLC digital output
address (See Section 5) to activate motor
2.