MANURE CONTROL
Input
9.3.3
Stacking Level Delay: Time before an alarm is generated when the stacking level is on. Set in
minutes.seconds
Warning Only
9.3.4
The alarm associated with the equipment will be consider as warning and won't stop any
sequence related to this equipment.
WARNING Valmetal
cause by enabling this option.
Current Factor
9.3.5
Multiply the input current by this value. Use for smart overload rated 40hp and higher (10x the
input current).
VFD Nominal Current (External VFD Only)
9.3.6
Nominal output current of the external VFD.
TECHNICAN'S MANUAL V0.3
/Valmetal Automation are not to be held responsible for any damage
2020-02-19
Rotation Probe Address: Address of the
PLC digital input for the rotation probe
Rotation Probe Active: Enable or disable
the rotation probe.
Rotation Probe Delay: Time before an
alarm is generated when the rotation
probe does not respond. Set in seconds.
Stacking Level Address: Address of the
PLC digital input for the stacking sensor.