Address Of Stop Command; Interlock - VALMETAL PAN-SPEC Manual

Table of Contents

Advertisement

MANURE CONTROL

Address of Stop Command

9.2.2
In that box you can modified the condition to stop the sequence. The stop command has priority
on the start command
HIGH/LOW:
The actual level must be higher than the setpoint.
The actual level must be lower than the setpoint.

Interlock

9.2.3
Stop a sequence or prevent it from starting if another sequence is started
TECHNICAN'S MANUAL V0.3
Address: Address of the PLC digital input.
Delay: Delay that the condition needs to be true to
stop the sequence.
Type: Normally open or normally closed contact.
Equipment: Programmed level sensor.
Start by Level %: level setpoint.
Select the sequences that will have priority on the sequence
you are programming. If two sequences have the interlock
enable between each other, the first to start have priority.
2020-02-19
28