Installing and Removing an I/O
Module/RAID Controller
Note: In the following section, "I/O Module" is taken to include
the RAID Controller in addition to the I/O Module.
The I/O module is located in the rear of the enclosure. Follow these
procedures to install and remove the I/O module.

Installing an I/O Module/RAID Controller

1
Remove the I/O module blank if there is one installed.
2
Gently insert the I/O module into the slot.
3
Secure in place using the two fixing screws (torque setting 0.3Nm).
4
Connect the cables as described in Chapter 3.

Removing an I/O Module/RAID Controller

1
Remove all cables.
2
Loosen the two fixing screws.
3
Using the module handle, gently slide the I/O Module out of the
slot.
Caution: Immediately replace the carrier or install an I/O module
blank to maintain correct airflow.
Chapter 6 Installing and Removing Components