Ls Module; Ls Module Features - Acer Altos S700 Series User Manual

Table of Contents

Advertisement

62

LS Module

The LS Module (Loop Resiliency and SES Module) provides monitoring
and control for the Altos S700 Series. The module reports status and
receives control information over the Enclosure Services Interface (ESI)
port of any of the fourteen disk drives installed in the enclosure. The LS
Module also provides loop resiliency for the Fibre Channel loop (in the
form of Port Bypass Circuits).
The Altos S700 Series contains one LS Module
second optional LS Module is available to provide active/passive fail-
over for the enclosure services communication, and to provide a
second Fibre Channel Loop. Only one LS Module communicates (using
ESI communication) with the host system at any one time, but both LS
modules will continuously monitor the system. If the active LS Module
fails, then the ESI communication with the host system will be taken
over by the passive LS Module.

LS Module Features

Monitoring/Control for 2 Power Supplies and 2 ACMs
Reports status and receives control information via the FC loop
Microcontroller for data processing, control and communications
Volatile and non-volatile memory for the microcontroller
Temperature sensor
Audible alarm with manual and software disable
FC link monitoring and status information
Firmware download capability
Reporting of PSU, LS module, I/O module, and backplane serial
number and revision
I/O module and backplane type reporting
Control of 6 front LEDs for enclosure and module status
I/O option slot status monitoring
1
For RAID configurations, there must be two LS modules installed.
Chapter 5 System Monitoring
1
as standard. However, a

Advertisement

Table of Contents
loading

This manual is also suitable for:

Altos s700f

Table of Contents