Important Information Regarding The Electrical Connection - RADEMACHER DuoFern 9482 Instruction Manual

1-10v
Table of Contents

Advertisement

8.2 Important information regarding the
i
electrical connection
Connection instructions for operating with
an external switch / button on site
◆ The voltage applied to the external input [ E ] is internally
decoupled and may also come from a phase other than [ L
] if required.
◆ The maximum length of lead to connect an external button
must not exceed 10 m.
Minimum length of insulation stripped:
Further installation instructions
◆ In order to ensure optimal operation, the DuoFern 1-10V
Controller should not be installed on a metallic base or near
metal objects.
◆ The DuoFern 1-10V Controller is intended for flush mounting.
We recommend installation in a deep 58 mm flush-mounted
box or in an electronic socket.
26
9 mm
All leads must be stripped to 9 mm.
EN