RADEMACHER DuoFern 9471-2 Instruction Manual

RADEMACHER DuoFern 9471-2 Instruction Manual

Motor actuator

Advertisement

Quick Links

DuoFern Motor Actuator 9471-2
EN
Instruction manual for the electrical connection and for commissioning
Item no. 3514 06 63
Type: 9471-2
VBD 621-22 (04.21)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DuoFern 9471-2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for RADEMACHER DuoFern 9471-2

  • Page 1 DuoFern Motor Actuator 9471-2 Instruction manual for the electrical connection and for commissioning Item no. 3514 06 63 Type: 9471-2 VBD 621-22 (04.21)
  • Page 2: Dear Customer

    Dear Customer, With your purchase of a DuoFern Motor Actuator 9471- 2 you have chosen a quality product manufactured by RADEMACHER. Thank you for the trust you have placed in us. RADEMACHER products have been developed with the greatest possible convenience in mind. Having applied uncompromising quality standards and thorough testing, we are proud to be able to present this innovative product to you.
  • Page 3: Table Of Contents

    Contents Dear Customer, ..............2 1. This manual.................4 How to use this manual ..............4 2. Hazard symbols ..............5 Levels of danger and signal words ..........5 Symbols and depictions used ............6 Glossary - definition ................7 3. Included in delivery ............8 4. Overview and connections ..........9 Operating buttons and indicator light ........10 5. Functional description ...........
  • Page 4: This Manual

    1. This manual..describes how to install, connect and commission the DuoFern Motor Actuator 9471-2. 1.1 How to use this manual ◆ Before you begin, please read this manual through completely and follow all the safety instructions. ◆ Please also read the instruction manual for the appliance being used.
  • Page 5: Hazard Symbols

    2. Hazard symbols The following hazard symbols are used in this manual: Risk of fatal electric shock Danger area / dangerous situation 2.1 Levels of danger and signal words DANGER! This hazard will lead to serious injury or death if not avoided. WARNING! WARNING! This hazard may result in serious injury or death if not avoided.
  • Page 6: Symbols And Depictions Used

    2.2 Symbols and depictions used Depiction Description Steps to be taken Itemisation ◆ 1) or a) Lists Further useful information Please read the respective manual...
  • Page 7: Glossary - Definition

    WR ConfigTool ◆ RADEMACHER software for programming the DuoFern Manual Control incl. automatic software updates for the DuoFern Manual Control. HomePilot® ◆ The HomePilot® is a central control unit for RADEMACHER radio products. ◆ Extra-low voltage SELV ◆ Safety extra-low voltage...
  • Page 8: Included In Delivery

    3. Included in delivery Included in delivery a) 1 x DuoFern Motor Actuator 9471-2 incl. antenna b) 1 x Instruction manual (not illustrated)
  • Page 9: Overview And Connections

    4. Overview and connections Pos. Symbol Description Control input ( Up / Down or On / Off ) Connection of an external switch / button for manual control on site. Potential-free relay contact - rotation direction (down) Connection of an electrical appliance (e.g. a motor).
  • Page 10: Operating Buttons And Indicator Light

    4.1 Operating buttons and indicator light Pos. Symbol Description Connect button Logging on to the DuoFern radio network or a DuoFern transmitter. STATUS Indicator light - status display green flashing Connection is active constantly Connection or disconnection lit up was successful flashes Control command briefly received flashing...
  • Page 11: Functional Description

    5. Functional description You can use the DuoFern Motor Actuator 9471-2 for the following applications: ◆ Control of motors with a different supply voltage (e.g. DC motors) ◆ Connection to the control inputs of other actuators and controllers ◆ Control of other suitable appliances Potential-free relay contacts The switching contacts of the DuoFern Motor Actuator 9471-2 are potential-free and isolated in terms of safety for the 230 V / 50 Hz...
  • Page 12: Functional Characteristics

    ● ● ● 15. Wind rotation direction Up / down ● ● ● 16. Rain function ● 17. Automatic rain function on / off on / off ● ● ● 18. Rain rotation direction Up / down ● ● ● The "WR ConfigTool" software can be downloaded from our website at www.rademacher.de.
  • Page 13 22. Reversal of rotation direction on / off ● ● ● ● ● 23. Connectivity test ● ● 24. Connect with radio code ● ● ● 25. E nd point setting for RADEMACHER tubular motors via radio 26. Reset via radio (3-stage) ● ● 27. Single-button operation 28. Jog mode ● ● 29. Venetian blind mode on / off ● ● ● 30. Standard slat position ** 0% - 100% ●...
  • Page 14: Technical Specifications

    6. Technical specifications Mains connection [ L / N ] Mains supply voltage: 230 V / 50 Hz Consumption: Standby: < 0.5 W Control input [ s E t ] for an external roller shutter switch / button on site Input voltage: 230 V / 50 Hz (Ri = 200 kW) Potential-free relay contacts - rotation direction [ s / t ] Maximum switching...
  • Page 15 6. Technical specifications Potential-free relay contacts - rotation direction [ s / t ] Maximum switching Capacitive loads such as: capacity for a 230V / electronic transformers, AC/DC 50 Hz   relay contact transformers, e.g. for extra-low voltage voltage bulbs such as halogen bulbs, LEDs, etc.
  • Page 16 6. Technical specifications DuoFern radio technology Transmission frequency: 434.5 MHz Transmission power: max. 10 mW Range: Indoors: approx. 30 m * Outdoors: approx. 100 m * Depending on the building structure Maximum number of DuoFern devices: General information Permissible ambient -20°C to + 55°C temperature: Dimensions (W x H x D):...
  • Page 17: Safety Instructions

    7. Safety instructions The use of defective devices can lead to personal injury and property damage (electric shocks / short circuiting). ◆ Never use defective or damaged devices. ◆ Check that the DuoFern Motor Actuator 9471-2 is intact. ◆ Consult our customer service department in the event that you discover damage, see page 32.
  • Page 18: Improper Use

    7.1 Intended use Radio systems that transmit on the same frequency can cause interference. ◆ A separate power supply (e.g. mains adapter) may be needed to supply power to the motor used. During installation, pay attention to the respective operating and installation conditions and check whether the motor power is within the range of the actuator's switching capacity.
  • Page 19: Expert Knowledge Required By The Installer

    7.2 Improper use There is a risk to life caused through short circuiting and electric shocks if the DuoFern Motor Actuator 9471-2 is used outside. ◆ Do not install and use the DuoFern Motor Actuator 9471-2 in a roller shutter box / outside or in damp rooms. 7.3 Expert knowledge required by the installer The electrical connection, installation and commissioning of the DuoFern Motor Actuator 9471- 2 must only be carried out by...
  • Page 20: Safety Instructions For The Electrical Connection

    Safety instructions for the electrical connection Prior to the electrical connection, check that the voltage / frequency on the type plate corresponds to that of the local mains supply. DANGER! There is a risk of fatal electric shock when touching electrical components.
  • Page 21: Important Information Regarding The Electrical Connection

    8.1 Important information regarding the electrical connection Connection instructions for operating with an external roller shutter switch / button on site ◆ It is imperative that a locking roller shutter switch / button is used in order to avoid increased current consumption and excessive heat build-up.
  • Page 22: Connecting And Installing The Duofern Motor Actuator 9471-2

    8.2 Connecting and installing the DuoFern Motor Actuator 9471-2 Ensure the mains are current-free and check whether the inlet leads are current-free. Securely lay all connecting cables right into the flush-mounted box. Remove the insulation on all leads down to 9 mm as specified above and connect them according to the following connection diagram.
  • Page 23: Connection Diagram (E.g. For 24 V Dc Motors)

    8.3 Connection diagram (e.g. for 24 V DC motors) 230 V / 50 Hz External roller shutter switch N PE Control input Up Control input Down STATUS RADEMACHER DuoFern Motor-Aktor 9471-2 Rotation direction Down/Up DC motor 24 V DC...
  • Page 24: Logging Duofern Transmitters On / Off

    9. Logging DuoFern transmitters on / off For the DuoFern Motor Actuator 9471- 2 to be operated with a DuoFern transmitter, you must log each desired transmitter onto the DuoFern Motor Actuator 9471- 2. You can log on a maximum of 20 DuoFern transmitters (e.g. DuoFern Manual Transmitter Standard, etc.).
  • Page 25: Logging On And Off Via Radio Code

    9.1 Logging on and off via radio code You can control the DuoFern Motor Actuator 9471- 2 directly using the radio code in order, for example, to be able to connect further DuoFern transmitters to the actuator after installation. You will find the radio code on the enclosed label and on the rear side of the DuoFern Motor Actuator 9471-2.
  • Page 26: Deleting All Settings (Reset)

    10. Deleting all settings (reset) A reset can be carried out to reset the DuoFern Motor Actuator 9471-2 to the default factory settings. Press and hold the disconnect button for approx. 5 seconds until the STATUS LED constantly lights up red. All of the settings are deleted and reset to the default factory settings and the logged-on DuoFern transmitters are automatically logged off.
  • Page 27: Dismantling

    11. Dismantling DANGER! There is a risk of fatal electric shock when touching electrical components. ◆ Disconnect all phases of the mains power lead and secure it to prevent any reconnection. Check that the system is de-energised. Log the DuoFern Motor Actuator 9471-2 off from the DuoFern network.
  • Page 28: Simplified Eu Declaration Of Conformity

    12. Simplified EU declaration of conformity RADEMACHER Geräte-Elektronik GmbH hereby declares that the DuoFern Motor Actuator 9471-2 complies with the Directive 2014/53/EU (Radio Equipment Directive). The full text of the declaration of conformity is available at the following website: www.rademacher.de/ce...
  • Page 29: Warranty Terms And Conditions

    13. Warranty terms and conditions You can find information about the warranty conditions of our products on our homepage.
  • Page 32 RADEMACHER Geräte-Elektronik GmbH Buschkamp 7 46414 Rhede (Germany)