Item
p) PulseGenerator
ClockPreScaler
1〜4096
PulseGeneratorClock (MHz)
0.0181274〜74.25
PulseGeneratorSelector
PulseGenerator0,
PulseGenerator1,
PulseGenerator2,
PulseGenerator3
PulseGeneratorLengthValue
1〜1048575
PulseGeneratorLength (ms)
PulseGeneratorFrequency (Hz)
PulseGeneratorClock (MHz) ÷
1048575 x 1000000 〜
PulseGeneratorClock (MHz) x
1000000
PulseGeneratorStartPointValue
0〜1048575
PulseGeneratorStartPoint (ms)
0〜42949.6
PulseGeneratorEndPointValue
1 〜 1048575
PulseGeneratorEndPoint (ms)
0〜42949.6
PulseGeneratorPulseWidth (ms)
PulseGeneratorRepeatCount
0 〜 255
PulseGeneratorClearActivation
Off,
LevelHigh,
LevelLow,
RisingEdge,
FallingEdge
PulseGeneratorClearSource
Exposure Active,
LVAL,
Pulse Generator[0 - 3],
UserOutput0, UserOutput1,
UserOutput2, UserOutput3,
Line4 TTL In 1,
Line5 Opt IN 1,
Line10 TTL In 2,
Line13 TTL In 3,
Logic Block 0, Logic Block 1,
Encoder Trigger
PulseGeneratorClearSyncMode
AsyncMode, SyncMode
Setting range
Default value
165
0.45
PulseGenerator0
30000
0
0
15000
0.15
0.15
0
Off
Low
AsyncMode
— 57 —
Description
Configure pulse generator settings.
Set the division value for the prescaler (12 bit) using PixelClock as the base
clock.
Set the clock used for the pulse generator.
This value is calculated using the [ClockPreScaler] value as a base.
Select the pulse generator.
Set the maximum count-up value as a clock count.
Set the maximum count-up value in milliseconds.
This value is calculated using the [PulseGeneratorLength] value as a base.
The setting range varies depending on the [ClockPreScaler] value.
Set the maximum count-up value as a frequency.
This value is calculated using the
[PulseGeneratorLength] value as a base.
Set the start point of the High interval as a clock count. When the counter
reaches this value, the output will be 1.
Set the start point of the High interval in milliseconds.
When the counter reaches this value, the output will be 1.
The setting range varies depending on the [ClockPreScaler] value.
Set the start point of the Low interval as a clock count. When the counter
reaches this value, the output will be 0.
Set the start point of the Low interval in milliseconds.
When the counter reaches this value, the output will be 0.
The setting range varies depending on the [ClockPreScaler] value.
Display the High interval width of the pulse in milliseconds.
The duration between the Start Point and End Point is calculated. The setting
range varies depending on the [ClockPreScaler] value.
Set the repeat count for the counter. When this is set to [0], a free counter is
enabled with no repeat limit.
Set the clear signal condition for the count clear input of the pulse generator.
Select the count clear input signal source.
Select the sync mode for the count clear input signal.