Stream 0, Stream 1 are two UDP streams, each assigned a different port number.
The assigned port number can be confirmed with the following settings.
In [TransportLayerControl] - [GevStreamChannelSelector], select the stream whose port number
you want to check, the port number will be displayed in [GevSCSP].
Setting the pixel format
The pixel format is set with [ComponentSelector] and [PixelFormat].
Single-Stream output
1. Select [RGB] in [ImageFormatControl] – [ComponentSelector].
2. Select [RGBa8] in [PixelFormat].
Dual-Stream output
First stream (Stream 0) setting.
1. Select [RGB] in [ImageFormatControl] – [ComponentSelector].
2. Select [RGB8, RGB10V1Packed, YUV422_8_UYVY or YUV422_8] in [PixelFormat].
Second stream (Stream 1) setting.
1. Select [NIR] in [ImageFormatControl] – [ComponentSelector].
2. Select [Mono8 or Mono10Packed] in [PixelFormat].
There are eleven combinations of PixelFormat that can be set as shown below.
1
Single-Stream
2
3
4
5
6
Dual-Stream
7
8
9
10
11
ComponentSelector = RGB
RGBa8
Stream 0
RGB8
RGB8
RGB10V1Packed
RGB10V1Packed
RGB10p32
RGB10p32
YUV422_8
YUV422_8
YUV422_8_UYVY
YUV422_8_UYVY
— 25 —
ComponentSelector = NIR
Stream 1
Mono8
Mono10Packed
Mono8
Mono10Packed
Mono8
Mono10Packed
Mono8
Mono10Packed
Mono8
Mono10Packed