PSENscan Configurator
2. Double-click the safety laser scanner from Network environment.
The safety laser scanner is displayed in the work window with IP address, firmware ver-
sion and status information.
3. Select Settings -> Change network settings.
Enter the password for the safety laser scanner (the factory default setting for the pass-
word is admin).
4. Enter the network data for connecting to the network and click OK.
5. The safety laser scanner switches to the OFF state. Click OK to continue.
6. The safety laser scanner is displayed automatically with an updated IP address.
7. Double-click on the device to create a new configuration.
8.3

Download configuration to device

You can use the Download configuration to device function to download the configura-
tion in the PSENscan Configurator to a connected device. Once the configuration test has
been completed, the new configuration in the connected device can be accepted or rejec-
ted.
Load configuration
1. Make sure that the Download configuration work window shows a report, listing the
differences between the existing configuration on the connected device and the config-
uration in the PSENscan Configurator.
The configuration on the connected device is labelled DEV.
The configuration in the PSENscan Configurator is labelled GUI.
2. Check the whole report to ensure it is correct.
3. Click on Load.
The configuration in the PSENscan Configurator is downloaded to the connected
device. The connected device goes offline as the configuration is being downloaded.
The configuration settings will not be available again until you Accept or Reject the
configuration.
4. Select Monitoring and check the downloaded configuration.
5. Select Download configuration and Accept or Reject the downloaded configuration.
Check
}
Click Accept to activate the downloaded configuration in the connected device and reject
the existing configuration on the connected device.
}
Click Reject to reject the downloaded configuration in the connected device and continue
to use the existing configuration on the connected device. The downloaded configuration
in the connected device will be deleted.
Operating Manual PSEN sc L 3/5 series
1005056-EN-01
| 63