Wiring

6
Wiring
6.1

General guidelines

}
Information given in the
}
Do not lay the connecting cable near or in contact with cables that carry high or highly
volatile currents.
}
Use separate cables to connect the wires to the OSSDs of different safety laser scanners
or safety switches.
}
For supply voltage, use only PELV/SELV power supplies that have a voltage buffer in ac-
cordance with EN 60204-1.
}
The protection type (see
Pilz connection leads available as an accessory.
}
Connection to evaluation devices
– Use the cables listed in the order reference (see
– The clamps for connection to the evaluation device must be kept in a locked control
}
Ensure compliance with permissible cable bending radii (see
6.2

Connector pin assignment

The safety laser scanner PSEN sc L 3/5 series has configurable inputs and outputs. In
PSENscan Configurator these can be configured for the specific application.
The safety laser scanner PSEN sc L 3/5 series has an 8-pin male connector and a 12-pin
male connector for connecting to the evaluation device and the supply voltage.
Use one of the two male connectors. The selected use has to be specified in PSENscan
Configurator.
}
Usage criteria of the 8-pin male connector
– Two configurable inputs, one configurable input/output
– Max. 3 zone sets
}
Usage criteria of the 12-pin male connector
– One configurable input, four configurable inputs/outputs
– Max. 10 zone sets
Operating Manual PSEN sc L 3/5 series
1005056-EN-01
Technical details [
Technical details [
accessories [
91])
cabinet. This prevents unauthorised modifications.
86]
must be followed.
86]) can only be achieved by using the
Order references for
Technical details [
86]).