Installation and alignment
7.6
Set the angle of inclination of the safety laser scanner
Procedure:
1. Change the inclination of the safety laser scanner within the permitted range of ± 6°.
If necessary, loosen the fixing screws for the safety laser scanner [3], the fine adjust-
ment screws for the inclination of the safety laser scanner [4] and the set screw for the
adjusting disc for angle of inclination [2].
Legend
[1]
[2]
[3]
[4]
2. Tighten the fixing screws for the safety laser scanner [3] with 3 Nm and tighten the fine
adjustment screws for the inclination of the safety laser scanner [4].
3. Tighten the set screw for the adjusting disc for angle of inclination [2] with 2,5 Nm.
7.7
Set the side inclination of the safety laser scanner
Prerequisites
}
The bracket PSEN sc bracket PR has to be installed at the mounting surface.
Procedure:
1. Change the side inclination of the safety laser scanner within the permitted range of
± 8.5°.
If required, loosen the roll angle fine adjustment screws [7] (see figure
setting of angle of inclination/roll angle - bracket PSEN sc bracket P [
2. Tighten the roll angle fine adjustment screws [7] (see figure
angle of inclination/roll angle - bracket PSEN sc bracket P [
Operating Manual PSEN sc L 3/5 series
1005056-EN-01
Adjusting disc for angle of inclination
Set screw for adjusting disc for angle of inclination
Fixing screws for safety laser scanner
Fine adjustment screws for the incline of the safety laser scanner
[1]
[3]
[2]
[4]
Installation with
55]).
Installation with setting of
55]) with 2,5 Nm.