Function description
4.11

Stationary hazardous area

Using the safety laser scanner, you can monitor a stationary danger zone, e.g. the environ-
ment of a machine that is installed in a fixed position.
The monitored area can be divided into subsections, for which monitoring can be activated
and deactivated each.
Legend
[1] Danger zone
[2] Configured zone 1, monitoring not activated
[3] Configured zone 2, monitoring not activated
4.12

Multiple evaluation

When multiple evaluation is active, an object has to be scanned several times consecut-
ively before the safety laser scanner switches the OSSDs to the OFF state. This reduces
the probability that insects, welding sparks or other particles lead to a shutdown of a plant.
If a multiple evaluation of 4 is configured, an object has to be detected 4 times in succes-
sion in the safety zone, so that the safety laser scanner switches the OSSDs to the OFF
state.
With a multiple evaluation > 2 an allowance has to be made to the response time. The
height of the allowance (see
the value of the multiple evaluation and the valid response time (see
details [
Operating Manual PSEN sc L 3/5 series
1005056-EN-01
[3]
Calculation of the overall response time [
86]).
[2]
[1]
32]) results from
Technical
| 21