ptzdriver
7.42 UART control (SD series)
Group: uart_i<0~(n-1)> n is uart port count
bit4 of capability_ptzenabled is 1)
NAME
cameraid
baudrate
databit
paritybit
stopbit
uartmode
316 - User's Manual
0~19,
1/4
127 (custom),
128 (no driver)
(capability.nuart > 0 and the bit7 of capability_ptzenabled is 0, the
VALUE
SECURITY
(get/set)
1~255
4/4
2400,4800,9600,19
4/4
200,38400,57600,1
15200
5,6,7,8
4/4
none,
4/4
odd,
even
1,2
4/4
rs485
4/7
The PTZ driver is used by this COM port.
DESCRIPTION
Camera ID controlling external PTZ camera.
Note:
Please set your speed dome to the
appropriate baud rate, and Camera ID, e.g.
2400bps, camera ID 1,2,3,,,,etc.
All Camera IDs on the same controlling
system (NVR or rs485 keyboard) have to be
distinct.
Therefore, once you send a controlling signal,
each camera will only accept the inputs with
the corresponding ID.
Set baud rate of COM port.