Checking Pilot And Burner Flames - Valor 738KN Installation & Owner's Manual

Gravity vent gas insert fireplace
Hide thumbs Also See for 738KN:
Table of Contents

Advertisement

OWNER'S
INFORMATION

Checking Pilot and Burner Flames

A periodic check of the pilot and burner fl ames should
be made. Check after the fi re has been on for at least
30 minutes. The pilot fl ame must cover the tip of the
thermocouple probe. The main burner fl ame pattern will
vary from appliance to appliance depending on the type
of installation and climatic conditions.
Correct fl ame appearance
739LSK—Traditional Logs
739DWK—Driftwood
739RSK—Rocks
Rock fuel bed
A black discoloration may form over time at the front
bottom of the 6-rock original fuel bed; this deposit
can be burned off by running the fi replace on a low
to medium setting fi re for 30 to 45 minutes. This
discoloration is unavoidable and will re-form again.
18
Servicing & Maintenance
The appliance area must always be kept clear and
free from combustible materials, gasoline and other
fl ammable vapors and liquids. Inspect the vent terminal
outdoors regularly to make sure that dirt, snow, insects,
leaves, shrubs, trees do not obstruct it. Examine the
whole vent system regularly. We recommend annually.
Thermocouple
probe must be
in flame
Pilot Flame can be seen on the
left side of the fuel bed

Advertisement

Table of Contents
loading

This manual is also suitable for:

G3 series738kp

Table of Contents