Control System Sequence - DeDietrich ALEZIO S V200 User Manual

Reversible air/water "split inverter" heat pump
Hide thumbs Also See for ALEZIO S V200:
Table of Contents

Advertisement

Parameter
Description
DM001
Domestic Hot Water tank temperature (bottom sensor) °C
DM006
Domestic Hot Water tank temperature (top sensor)
DM009
Automatic/derogation status of Domestic Hot Water
mode:
0 =Scheduling
1 = Manual
2 =Antifrost
3 =Temporary
DM029
Domestic Hot Water temperature setpoint
HM001
Heat pump flow temperature after condenser
HM002
Heat pump return temperature after condenser.
HM033
Flow temperature setpoint in cooling mode
HM046
Heat pump 5V signal output setpoint
PM002
External winning Central Heating setpoint
Fxx.xx
Software version for the selected PCB
Pxx.xx
Parameter version for the selected PCB
Tab.28
Values available (X) in the
Parameter
Fxx.xx
Pxx.xx
7.1

Control system sequence

Tab.29
List of statuses and sub-statuses
Status Appliance: AM012 parameter
0
1= heating / cooling / domestic hot water de­
mand
7682850 - v04 - 02082019
sub-menu
Description
HMI software version
HMI parameter version
Appliance sub status: AM014 parameter
00= total system shut-down
Heat Demand
00 = off
The set point is reached. The compressor can start up whenever necessary.
01= anti-short cycle
The heating set point has been reached. The compressor is not authorised to
restart.
02= reversal valve switch to heating position
03= power supply to the hybrid pump
04= pending start-up conditions on the heat pump and the back-ups
62= three-way valve switch to domestic hot water position
7 Reading out measured values
Unit
EHC-04
X
X
°C
X
°C
X
°C
X
°C
X
°C
X
V
X
°C
X
X
X
EHC--04
X
X
SCB04-B
X
X
SCB04-B
X
X
MIV-4S V200
37