3. Remove the right UV-lamp assembly:
a. Disconnect the UV power cable and the fan power cable.
b. Remove the screw that secures the right UV lamp, and then pull and
lift up the UV lamp.
4. Loosen the two screws securing the suction tube on the print block.
5. Lift the suction tube to secure it in a raised position.