3. LASER SAFETY INFORMATION

The instrument is classified as the following class of Laser Product according to IEC Standard
Publication 60825-1 Ed.2.0: 2007 and United States Government Code of Federal Regulation FDA
CDRH 21CFR Part 1040.10 and 1040.11 (Complies with FDA performance standards for laser
products except for deviations pursuant to Laser Notice No.50, dated June 24, 2007.)
EDM device in objective lens
Laser plummet (option)
AVOID EXPOSURE-Laser radiation
is emitted from this aperture.
Laser beam emitted
from here
*
* Laser beam emitted from here
(only when laser plummet
function is mounted)
• EDM device is classified as Class 3R Laser Product when reflectorless measurement is selected.
When target (reflector) is set to prism or reflective sheet, the output is equivalent to the safer class 1.
Warning
• Use of controls or adjustments or performance of procedures other than those specified herein may
result in hazardous radiation exposure.
• Follow the safety instructions on the labels attached to the instrument as well as in this manual to
ensure safe use of this laser product.
• Never intentionally point the laser beam at another person. The laser beam is injurious to the eyes
and skin. If an eye injury is caused by exposure to the laser beam, seek immediate medical attention
from a licensed ophthalmologist.
Device
Light beam used for measurement
(When target (reflector) is set to N-prism.)
Light beam used for measurement
(When target (reflector) is set to prism or
reflective sheet.)
Laser-pointer
LASER RADIATION
AVOID DIRECT EYE EXPOSURE
MAX 5mW LD 625-695nm
CLASS3R LASER PRODUCT
IEC 60825-1 Ed. 2.0 : 2007
8
Laser class
Class 3R
Class 1
Class 3R
Class 2