9.3

Connection via RS232C Cable

RS232C communication is possible, connecting instrument and a data collector with the cable.
PROCEDURE Basic cable settings
1. Power OFF the instrument and connect the
instrument and a data collector with a interface
cable.
Cables: "27. OPPTIONAL ACCESSORIES"
2. Select "Comms" in Config mode.
Set communication conditions in the "Comms
setup" tab. Set "Comms mode" to "RS232C".
3. Set options in the "RS232C" tab according to the
selection made in the "Comms setup" tab.
Items set and options (*: Factory setting)
(1) Baud rate: 1200/2400/4800/9600*/19200/
38400bps
(2) Data bits: 7/8* bits
(3) Parity
: Not set*/Odd/Even
(4) Stop bit : 1*/ 2 bits
4. Press [OK] to finish settings.
9. CONNECTING TO EXTERNAL DEVICES