7.4 Technical data

7.4
Technical data
7.4.1

General technical specifications

General technical specifications
Weight without mounting brackets Approx. 1.4 kg
Power supply
Power consumption (DC)
Current consumption
Noise emission
Degree of protection
Protection class
Overvoltage Category
Pollution Degree
Quality assurance
: The device may only be connected to a 24 VDC power supply which meets the requirements of a
1
safe extra-low voltage (SELV/PELV) in accordance with IEC/EN/DIN EN/UL 61010-2-201. The power
supply must fulfill the requirements of Limited Energy according to IEC/EN/DIN EN/UL 61010-2-201.
Electromagnetic compatibility
Radiation Emission (Enclosure port)
in accordance with IEC 61000-6-3
+ A1/ CAN/CSA-CISPR 22:10
Immunity with regard to conduct-
ed interference on the supply lines
66
1
< 55 dB(A) according to DIN 45635-1
IP40 in accordance with IEC 60529
Protection class I in accordance with IEC 61140
II
2
In accordance with ISO 9001
24 VDC (19.2 to 28.8V)
Rated output power: 30W
40%~60% full load, 24 VDC at 85% efficiency
Pout ≥ 6W, 24 VDC at 70% efficiency
Pout < 6W, 24 VDC at 50% efficiency
Max. 2.3 A at 19.2 V
Max. 1.9 A at 24 V
Max. 1.6 A at 28.8 V
30 to 230 MHz: 30 dB(µV/m) Quasi-peak (10 m distance)
230 to 1000 MHz: 37 dB (µV/m) Quasi-peak (10 m distance)
1 to 3 GHz: 70 dB (µV/m) Peak; 50 dB (µV/m) Average (3 m
distance)
3 to 6 GHz: 74 dB (µV/m) Peak; 54 dB (µV/m) Average (3 m
distance)
± 2 kV (5 kHz /100 kHz) in accordance with IEC 61000-4-4;
Burst
± 1kV line to line, ±2 kV line to earth in accordance with IEC
61000-4-5; Surge
Operating Instructions, 06/2021, A5E50059933-AA