8.4

Technical data

8.4.1

General technical specifications

General technical specifications
Size of the device
Weight
Power supply
Power consumption (DC)
Current consumption
Noise emission
Degree of protection
Protection class
Pollution Degree
Quality assurance
: The device may only be connected to a 24 V DC power supply which meets the requirements of a
1
safe extra-low voltage (SELV/PELV) in accordance with IEC/EN/DIN EN/UL 61010-2-201.
Electromagnetic compatibility
Radiation Emission (Enclosure port)
in accordance with IEC 61000-6-3
+ A1/ CAN/CSA-CISPR 22:10
Immunity with regard to
conducted interference on the
supply lines
SIMATIC IPC277G PRO
Operating Instructions, 02/2022, A5E51373692-AA
12" device
12" device: Approx. 4500 g
1
24 V DC (19.2 to 28.8 V)
Rated output power: 30 W
40%~60% full load, 24 V DC
at 85% efficiency
Pout ≥ 6 W, 24 V DC at 70%
efficiency
Pout < 6 W, 24 V DC at 50%
efficiency
Max. 1.9 A at 24 V
< 55 dB(A) according to DIN 45635-1
IP 65 to IEC60529
Enclosure nach UL50 Type 4X (indoor use only) / Type 12
Protection class III in accordance with IEC 61140
2
In accordance with ISO 9001
15" and 19" device
15" device: Approx. 5900 g
19" device: Approx. 6900 g
24 V DC (19.2 to 28.8 V)
Rated output power: 80 W
50% to 100% nominal output power,
24 V DC at 85% efficiency
Max. 5.0 A at 24 V
30 to 230 MHz: 30dB(uV/m) quasi-peak(10m distance)
230 to 1000 MHz: 37dB(uV/m) quasi-peak(10m distance)
1 to 3 GHz: 76dB(uV/m) peak; 56dB(uV/m) average (3m
distance)
3 to 6 GHz: 74dB(uV/m) peak; 54dB(uV/m) average (3m
distance)
Burst: ± 2 kV (5 kHz /100 kHz) in accordance with IEC 61000-
4-4;
Surge: ± 1kV line to line, ±2 kV line to earth in accordance
with IEC 61000-4-5;