Event Function; Action To Be Taken Upon An Event Occurrence - Panasonic WJ-NX200G Operating Instructions Manual

Network disk recorder
Hide thumbs Also See for WJ-NX200G:
Table of Contents

Advertisement

[Operation via recorder's main monitor]

Event function

The recorder will take an event action when any of the following events occur.
• Terminal alarm:
• Camera site alarm:
• Command alarm:

Action to be taken upon an event occurrence

When the recorder recognizes an event, it will take an event action according to the set action mode.
Event action mode
In the event modes shown below, the recorder takes one of the following event actions when an event occurs.
The event action mode can be configured on the setup menu. (☞ Page 41)
Recording & alarm action: Performs all event actions according to the settings. ("A" in the following table)
Recording only:
Off:
A different event action will be taken depending on the selected event action mode. Refer to a system adminis-
trator for further information.
Event action
Recording
Start event recording
Define pre-event recording
Alarm action
Move the camera to the
preset position
Blink the alarm indicator
Sound the buzzer
Outputs alarm signals
Display event information on
the main monitor
Display the alarm icon on a
web browser
Display the alarm message
on a web browser
Record the alarm logs*
An event when an alarm input signal is supplied from an external device such as a
door sensor to the alarm input terminal on the rear of the recorder.
An event when an alarm (camera terminal alarm, etc.) is detected by a camera.
An alarm when receiving an alarm from a PC, etc. via a network.
Performs only recording, filing alarm logs, and moving to camera presets. ("B" in the
following table)
Files only alarm logs. ("C" in the following table)
Description
Recording will start according to the recording
duration configured on the setup menu.
Camera images recorded before an event occurs can
be associated with the event and saved on the hard
disk.
Move the camera to the preset position registered in
advance.
The alarm indicator on the front panel will start
blinking.
The buzzer will start sounding for the duration set in
advance.
Output signals will be sent from the ALARM/
CONTROL connector at the rear of the recorder.
The event type and terminal/camera number will be
displayed on the status display panel. At the same
time, the alarm button turn red.
The alarm icon will be displayed on the event error
display area of the web browser.
A window that notifies of an event occurrence will be
displayed on the web browser.
* The alarm message displayed last has priority. To
close the window, click the [×] button.
2
Date & time of the event and event information will be
recorded in a log list.
118
1
Mode*
A
B
C
×
×
×
×
×
×
×
×
×
×
×
×
×
×

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wj-nx200k

Table of Contents