10-3. Indoor Unit

10-3-1. Installation place

• A place which provides the spaces around the
indoor unit as shown in the diagram
• A place where there are no obstacles near the air
inlet and outlet
A place which allows easy installation of the piping
to the outdoor unit
A place which allows the front panel to be opened
The indoor unit shall be installed at least 2.5 m height.
Also, it must avoided to put anything on the top of the
indoor unit.
CAUTION
• Direct sunlight to the indoor unit's wireless
receiver should be avoided.
• The microprocessor in the indoor unit should not
be too close to RF noise sources.
(For details, see the owner's manual.)
<Remote control>
• A place where there are no obstacles such as a
curtain that may block the signal from the indoor
unit.
• Do not install the remote control in a place exposed
to direct sunlight or close to a heating source, such
as a stove.
• Keep the remote control at least 1 m apart from the
nearest TV set or stereo equipment. (This is
necessary to prevent image disturbances or noise
interference.)
• The location of the remote control should be
determined as shown below.
(Side view)
Remote
Reception
control
range
Fig. 10-3-1
(Top view)
Indoor unit
Reception
range
Remote
control

10-3-2. Cutting a hole and mounting installation

<Cutting a hole>
When installing the refrigerant pipes from the rear.
The center of the pipe hole
is above the arrow.
1. After determining the pipe hole position on the
mounting plate (A), drill the pipe hole (∅ 65 mm) at
a slight downward slant to the outdoor side.
NOTE
• When drilling a wall that contains a metal lath, wire
lath or metal plate, be sure to use a pipe hole brim
ring sold separately.
<Mounting the installation plate>
Pipe hole
Indoor unit
- 62 -
FILE NO. SVM-19001
Pipe hole
120 mm
Fig. 10-3-2
Hook
Hook
Hook
Thread
Pipe hole
Weight
5
Mounting screw
Fig. 10-3-3
Ø65 mm
65
103
1
Installation
plate

Hide quick links: